SEN00718-01 40 Troubleshooting Failure code [D190KA] ACC signal relay: Disconnection 1 50 D155AX-6 Action code Failure code Trouble ACC signal relay: Disconnection (Power train controller system) – D190KA Contents of trouble • When ground circuit of ACC signal drive relay circuit is disconnected, no current flows. Action of controller • Turns signal to ACC signal drive relay circuit OFF. Problem that appears on machine • Turbo-timer function does not operate (if turbo-timer is installed). • Machine is not affected particularly (if turbo-timer is not installed). Related information • State of ACC signal drive relay circuit signal can be checked with monitoring function. (Code:
60500 ENG Hold Relay) • Method of reproducing failure code: Turn starting switch ON o OFF (if turbo-timer is installed). • This failure code detects abnormality on primary side (coil side) of ACC signal drive relay but does not detect abnormality on secondary side (contact side). Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective ACC signal drive relay (Internal disconnection) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON.
EHL (male) Resistance Between (1) – (2) 200 – 400 z 2 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between STC2 (female) (9) – EHL (female) (2) Resis- tance Max. 1 z Wiring harness between EHL (female) (1) – branch point (J) Resis- tance Max. 1 z 3 Hot short (Short circuit with 24V circuit) in wiring harness a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. Wiring harness between STC2 (female) (9) – EHL (female) (2) and chassis ground Voltage Max.
1 V 4 Defective power train con- troller a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. STC2 (female) Resistance Between (9) – chassis ground 200 – 400 z