Komatsu D155AX-6 — FAILURE CODE [D190KB] ACC SIGNAL RELAY: SHORT CIRCUIT

SEN00718-01 40 Troubleshooting Failure code [D190KB] ACC signal relay: Short circuit 1 52 D155AX-6 Action code Failure code Trouble ACC signal relay: Short circuit (Power train controller system) – D190KB Contents of trouble • When ground circuit of ACC signal drive relay was disconnected, abnormal current flowed. Action of controller • Turns output of ACC signal drive relay circuit OFF. Problem that appears on machine • Turbo-timer function does not operate (if turbo-timer is installed). • Machine is not affected particularly (if turbo-timer is not installed). Related information • State of ACC signal drive relay circuit signal can be checked with monitoring function. (Code:

60500 ENG Hold Relay) • Method of reproducing failure code: Turn starting switch ON o OFF (if turbo-timer is installed). • This failure code detects abnormality on primary side (coil side) of ACC signal drive relay but does not detect abnormality on secondary side (contact side). Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective ACC signal drive relay (Short circuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON.

EHL (male) Resistance Between (1) – (2) 200 – 400 z 2 Ground fault in wiring har- ness (Contact with GND cir- cuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between STC2 (female) (9) – EHL (female) (2) and chassis ground Resis- tance 1 Mz 3 Defective power train con- troller a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. STC2 (female) Resistance Between (9) – chassis ground 200 – 400 z