Komatsu D155AX-6 — FAILURE CODE [D5ZKKX] THROTTLE DIAL: OUT OF NORMAL RANGE

SEN00718-01 40 Troubleshooting Failure code [D5ZKKX] Throttle Dial: Out of normal range 1 54 D155AX-6 Action code Failure code Trouble Throttle Dial: Out of normal range (Power train controller system) E03 D5ZKKX Contents of trouble • Signal voltage of fuel control dial is below 0.30 V or above 4.55 V. Action of controller • Continues control with decelerator pedal potentiometer signal. • Limits operation of engine and transmission. Problem that appears on machine • Once machine is stopped, engine speed is limited to medium (half). • Once machine is stopped, travel is limited to F1 and R1. Related information • State of fuel control dial can be checked with monitoring function. (Code:

03000 Fuel Dial Sensor) • Method of reproducing failure code: Turn starting switch ON. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective sensor 5V power supply system If failure code [DBE7KK] is also displayed, carry out troubleshoot- ing for it first. 2 Defective fuel control dial (Internal disconnection or short circuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON.

DIAL (male) Resistance Between (1) – (3) 4.0 – 6.0 kz Between (1) – (2) 0.25 – 7.0 kz Between (2) – (3) 0.25 – 7.0 kz 3 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between STC1 (female) (22) – DIAL (female) (1) Resis- tance Max. 1 z Wiring harness between STC1 (female) (1) –DIAL (female) (2) Resis- tance Max. 1 z 4 Ground fault in wiring har- ness (Contact with GND cir- cuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON.

Wiring harness between STC1 (female) (1) – DIAL (female) (2) and chassis ground Resis- tance Min. 1 Mz 5 Hot short (Contact with GND circuit) in wiring harness a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. Wiring harness between STC1 (female) (1) – DIAL (female) (2) and chassis ground Voltage Max. 1 V 6 Defective power train con- troller a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. STC1 Voltage Between (1) – (21) 0.30 – 4.33 V