SEN00719-01 40 Troubleshooting Failure code [DB97KK] WE controller: Source voltage reduction 1 6 D155AX-6 Action code Failure code Trouble WE controller: Source voltage reduction (Work equipment controller system) E03 DB97KK Contents of trouble • Voltage of 5V power supply circuit for work equipment controller sensors is below 4.5 V or above 5.5 V. • Abnormal current flowed in 5V power supply circuit for work equipment controller sensors. Action of controller • Turns output of 5V power supply circuit OFF, if abnormal current flows. • Limits operation of engine and transmission. Problem that appears on machine • System may not operate normally.
• Once machine is stopped, engine speed is limited to medium (half). • Once machine is stopped, travel is limited to F1 and R1. Related information • Method of reproducing failure code: Turn starting switch ON. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective blade control lever or ripper control lever (Inter- nal trouble) a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. Disconnect devices at right in order.If "E" of failure code disap- pears when a device is disconnected, that device has trouble in it.
Blade control lever Connector WLV1 Ripper control lever Connector WLV2 2 Ground fault in wiring har- ness (Contact with GND cir- cuit) a Prepare with starting switch OFF, then carry out trouble- shooting without turning starting switch ON. Wiring harness between WEC1 (female) (22) – WLV1 (female) (4), (8) and chassis ground [Blade control lever system] Resis- tance Min. 1 Mz Wiring harness between WEC1 (female) (22) – WLV2 (female) (4), (8) and chassis ground [Ripper control lever system] Resis- tance Min. 1 Mz 3 Hot short (Short circuit with 24V circuit) in wiring harness a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting.
Wiring harness between WEC1 (female) (22) – WLV1 (female) (4), (8) and chassis ground [Blade control lever system] Voltage Max. 1 V Wiring harness between WEC1 (female) (22) – WLV2 (female) (4), (8) and chassis ground [Ripper control lever system] Voltage Max. 1 V 4 Defective work equipment controller a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. WEC1 Voltage Between WEC1(22) – (21) 4.5 – 5.5 V