SEN00719-01 40 Troubleshooting Failure code [DB99KQ] WE controller: Type select signal 1 z Circuit diagram related to work equipment controller type select power supply 8 D155AX-6 Action code Failure code W Trouble ( E controller: Type select signal Work equipment controller system) E04 DB99KQ Contents of trouble • Specification setting in work equipment controller does not match to specification setting sign (Work equipment controller cannot be recognized). Action of controller • Turns all outputs of work equipment controller OFF. • Limits operation of engine and transmission. Problem tha appears on machine t • Machine does not move at all.
• Once machine is stopped, engine speed is limited to medium (half). • Once machine is stopped, it cannot travel at all. Related information • Method of reproducing failure code: Turn starting switch ON. Possible caus and standar value in norm state Cause T o Defective adjustment of work 1 p equipment controller • es Disconnection in wiring har- a d ness (Disconnection in wiring al 2 or defective contact in con- W nector) (3 a Defective work equipment 3 controller Standard value in normal state/Remarks on troubleshootin urn Adjustment function in service mode ON and perform peration of reproducing trouble. If "E" of failure code disap ears at this time, system is normal. Adjustment code:
0031 (Initialization of work equipment controller) Prepare with starting switch OFF, then carry out trou shooting without turning starting switch ON. iring harness between WEC3 (female) 0) – chassis ground (GND11) Resis- tance Max. Prepare with starting switch OFF, then turn starting sw ON and carry out troubleshooting. WEC3 Voltage Wiring harness between (30) – chassis ground Max. 1 V