SEN00719-01 40 Troubleshooting Failure code [DD12KB] Shift up Sw: Short circuit 1 24 D155AX-6 Action code Failure code Trouble Shift up Sw: Short circuit (Power train controller system) E02 DD12KB Contents of trouble • Signals of 2 systems of shift-up switch circuit are turned ON (closed) simultaneously. Action of controller • Recognizes that shift-up switch is not pressed. Problem that appears on machine • Transmission gear cannot be shifted up. • Auto shift-down function does not operate. Related information • "NO" signal of 2 systems of switch is for sensing operation and "NC" signal is for detecting error. • State of shift-up switch signal can be checked with monitoring function. (Code:
40905 T/M Sw Input 1) • Method of reproducing failure code: Turn starting switch ON + Operate shift-up switch. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective shift-up switch (Internal short circuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. SFTU (male) Shift-up switch OFF (Released) ON (Pressed) Resistance between (3) – (2) Max. 1 z Min. 1 Mz Resistance between (1) – (2) Min. 1 Mz Max.
1 z 2 Ground fault in wiring har- ness (Contact with GND cir- cuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between STC3 (female) (9) – SFTU (female) (1) and chassis ground Resis- tance Min. 1 Mz Wiring harness between STC1 (female) (12) – SFTU (female) (3) and chassis ground Resis- tance Min. 1 Mz 3 Defective power train con- troller a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. STC1 ,STC3 Shift-up switch OFF (Released) ON (Pressed) Voltage between STC1 (12) – STC1 (4) Max. 1 V 5 – 11 V Voltage between STC3 (9) – STC1 (4) 5 – 11 V Max. 1 V