SEN00719-01 40 Troubleshooting Failure code [DD13KB] Shift down Sw: Short circuit 1 28 D155AX-6 Action code Failure code Trouble Shift down Sw: Short circuit (Power train controller system) E02 DD13KB Contents of trouble • Signals of 2 systems of shift-down switch circuit are turned ON (closed) simultaneously. Action of controller • Recognizes that shift-down switch is not pressed. Problem that appears on machine • Transmission gear cannot be shifted down. • Auto shift-down function does not operate. Related information • "NO" signal of 2 systems of switch is for sensing operation and "NC" signal is for detecting error.
• State of shift-down switch signal can be checked with monitoring function. (Code: 40905 T/M Sw Input 1) • Method of reproducing failure code: Turn starting switch ON + Operate shift-down switch. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective shift-down switch (Internal disconnection) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. SFTD (female) Shift-down switch OFF (Released) ON (Pressed) Resistance between (3) – (2) Max. 1 z Min. 1 Mz Resistance between (1) – (2) Min. 1 Mz Max.
1 z 2 Ground fault in wiring har- ness (Contact with GND cir- cuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between STC1 (female) (18) – SFTD (female) (1) and chassis ground Resis- tance Min. 1 Mz Wiring harness between STC1 (female) (24) – SFTD (female) (3) and chassis ground Resis- tance Min. 1 Mz 3 Defective power train con- troller a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. STC1 Shift-down switch OFF (Released) ON (Pressed) Voltage between (24) – (4) Max. 1 V 5 – 11 V Voltage between (18) – (4) 5 – 11 V Max. 1 V