SEN00719-01 40 Troubleshooting Failure code [DDN7KB] WEQ Knob Sw (down): Short circuit 1 42 D155AX-6 Action code Failure code Trouble WEQ Knob Sw (down): Short circuit (Work equipment controller system) E02 DDN7KB Contents of trouble • Signals of 2 systems of blade pitch switch circuit are turned ON (closed) simultaneously. Action of controller • Recognizes that blade pitch switch is not pressed. Problem that appears on machine • Blade pitch function does not operate. Related information • "NO" signal of 2 systems of switch is for sensing operation and "NC" signal is for detecting error. • State of blade pitch switch signal can be checked with monitoring function. (Code:
70300 Blade Sw Input) • Method of reproducing failure code: Turn starting switch ON + Operate blade pitch switch. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective blade pitch switch (Internal short circuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. BNSL (female) Blade pitch switch OFF (Released) ON (Pressed) Resistance between (3) – (2) Max. 1 z Min. 1 Mz Resistance between (1) – (2) Min. 1 Mz Max.
1 z 2 Ground fault in wiring har- ness (Contact with GND cir- cuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between WEC2 (female) (16) – BNSL (female) (1) and chassis ground Resis- tance Min. 1 Mz Wiring harness between WEC2 (female) (6) – BNSL (female) (3) and chassis ground Resis- tance Min. 1 Mz 3 Defective work equipment controller a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. WEC1, WEC2 Blade pitch switch OFF (Released) ON (Pressed) Voltage between WEC2 (6) – WEC1 (4) Max. 1 V 5 – 11 V Voltage between WEC2 (16) – WEC1 (4) 5 – 11 V Max. 1 V