SEN00719-01 40 Troubleshooting Failure code [DDNLKA] Weq lock Sw: Disconnection 1 48 D155AX-6 Action code Failure code Trouble Weq lock Sw: Disconnection (Work equipment controller system) E03 DDNLKA Contents of trouble • Signals of 2 systems of work equipment lock lever switch circuit are turned OFF (opened) simulta- neously. Action of controller • Recognizes that work equipment lock lever is in FREE position. • Limits operation of engine and transmission. Problem that appears on machine • Once machine is stopped, engine speed is limited to medium (half). • Once machine is stopped, travel is limited to F1 and R1.
Related information • "NO" signal of 2 systems of switch is for sensing operation and "NC" signal is for detecting error. • State of blade float switch signal can be checked with monitoring function. (Code: 70300 Blade Sw Input) • Method of reproducing failure code: Turn starting switch ON + Operate work equipment lock lever. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective work equipment lock lever switch (Internal disconnection) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON.
WELK (male) Work equipment lock lever FREE position LOCK position Resistance between (B) – (A) Max. 1 z Min. 1 Mz Resistance between (C) – (A) Min. 1 Mz Max. 1 z 2 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between WEC1 (female) (10) – WELK (female) (A) Resis- tance Max. 1 z Wiring harness between WEC2 (female) (5) – WELK (female) (B) Resis- tance Max. 1 z Wiring harness between WEC2 (female) (15) – WELK (female) (C) Resis- tance Max.
1 z 3 Hot short (Short circuit with 24V circuit) in wiring harness a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. Wiring harness between WEC2 (female) (5) – WELK (female) (B) and chassis ground Voltage Max. 1 V Wiring harness between WEC2 (female) (15) – WELK (female) (C) and chassis ground Voltage Max. 1 V 4 Defective work equipment controller a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. WEC1, WEC2 Work equipment lock lever FREE position LOCK position Voltage between WEC2 (5) – WEC1 (10) Max. 1 V 5 – 11 V Voltage between WEC2 (15) – WEC1 (10) 5 – 11 V Max. 1 V