SEN00719-01 40 Troubleshooting Failure code [DDTSL1] S/C: Fill high 1 52 D155AX-6 Action code Failure code Trouble S/C: Fill high (Power train controller system) E02 DDTSL1 Contents of trouble • When signal is not output to solenoid circuit of torque converter stator clutch ECMV, fill switch signal is turned ON. Action of controller • None in particular. Problem that appears on machine • Travel torque may not be obtained sufficiently. Related information • State of fill switch signal of stator clutch ECMV can be checked with monitoring function. (Code: 31520 T/M Fill Sw Input 2) • Method of reproducing failure code: Start engine + Set travel lever in N (Neutral).
Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective fill switch of stator clutch ECMV (Internal short circuit) a Prepare with starting switch OFF, then start engine, select automatic gearshift mode, and carry out troubleshooting. FSTC (male) PCCS lever (Travel gear speed) Resistance Between (1) – chas- sis ground N Max. 1 z Locked up at F1, F2, or F3 Min. 1 Mz 2 Ground fault in wiring har- ness (Contact with GND cir- cuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON.
Wiring harness between STC2 (female) (26) – FSTC (female) (1) and chassis ground Resis- tance Min. 1 Mz 3 Defective power train con- troller a Prepare with starting switch OFF, then start engine, select automatic gearshift mode, and carry out troubleshooting. STC2 PCCS lever (Travel gear speed) Voltage Between (26) – chas- sis ground N Max. 1 V Locked up at F1, F2, or F3 5 – 11 V 4 Defective hydraulic system If causes 1 – 3 are not detected in electrical system, hydraulic sys- tem may be defective. Carry out related troubleshooting (H mode).