SEN00720-01 40 Troubleshooting Failure code [DFA6KA] BL lever 2: Disconnection 1 10 D155AX-6 Action code Failure code Trouble BL lever 2: Disconnection (Work equipment controller system) E03 DFA6KA Contents of trouble • Signal voltage of blade control lever lift potentiometer 2 system is below 0.5 V. Action of controller • Continues control with signal of blade control lever lift potentiometer 1 system. • Limits operation of engine and transmission. Problem that appears on machine • Once machine is stopped, engine speed is limited to medium (half). • Once machine is stopped, travel is limited to F1 and R1.
Related information • State of blade control lever lift potentiometer 2 signal can be checked with monitoring function. (Code: 73401 Blade Lift Lever B Potentio) • Method of reproducing failure code: Turn starting switch ON + Operate blade control lever (in lifting direction). Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective sensor 5V power supply system If failure code [DB97KK] is also displayed, carry out troubleshoot- ing for it first.
2 Defective blade control lever lift potentiometer 2 (Internal disconnection) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. WLV1 (male) Blade control lever Resistance Between (4) – (1) Neutral 3.2 kz ± 20 % Between (4) – (2) 1.6 kz ± 20 % Between (2) – (1) 1.6 kz ± 20 % 3 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between WEC1 (female) (22) – WLV1 (female) (4) Resis- tance Max. 1 z Wiring harness between WEC1 (female) (19) – WLV1 (female) (2) Resis- tance Max.
1 z 4 Ground fault in wiring har- ness (Contact with GND cir- cuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between WEC1 (female) (19) – WLV1 (female) (2) and chassis ground Resis- tance Min. 1 Mz 5 Defective work equipment controller a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. WEC1 Voltage Between (19) – (21) 0.5 – 4.5 V