Komatsu D155AX-6 — FAILURE CODE [DFA6KB] BL LEVER 2: SHORT CIRCUIT

SEN00720-01 40 Troubleshooting Failure code [DFA6KB] BL lever 2: Short circuit 1 12 D155AX-6 Action code Failure code Trouble BL lever 2: Short circuit (Work equipment controller system) E03 DFA6KB Contents of trouble • Signal voltage of blade control lever lift potentiometer 2 system is above 4.5 V. Action of controller • Continues control with signal of blade control lever lift potentiometer 1 system. • Limits operation of engine and transmission. Problem that appears on machine • Once machine is stopped, engine speed is limited to medium (half). • Once machine is stopped, travel is limited to F1 and R1.

Related information • State of blade control lever lift potentiometer 2 signal can be checked with monitoring function. (Code: 73401 Blade Lift Lever B Potentio) • Method of reproducing failure code: Turn starting switch ON + Operate blade control lever (in lifting direction). Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective sensor 5V power supply system If failure code [DB97KK] is also displayed, carry out troubleshoot- ing for it first.

2 Defective blade control lever lift potentiometer 2 (Internal short circuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. WLV1 (male) Blade control lever Resistance Between (4) – (1) Neutral 3.2 kz ± 20 % Between (4) – (2) 1.6 kz ± 20 % Between (2) – (1) 1.6 kz ± 20 % 3 Hot short (Short circuit with 24V circuit) in wiring harness a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. Wiring harness between WEC1 (female) (19) – WLV1 (female) (2) and chassis ground Voltage Max.

1 V 4 Defective work equipment controller a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. WEC1 Voltage Between (19) – (21) 0.5 – 4.5 V