SEN00720-01 40 Troubleshooting Failure code [DFADKX] RL lever 1: Out of normal range 1 Failure code [DFADKZ] RL lever: Disconnection or short circuit 1 34 D155AX-6 Action code Failure code Trouble RL lever 1: Out of normal range (Work equipment controller system) E03 DFADKX Contents of trouble • In ripper control lever tilt potentiometer 1 and 2 systems, either of failure codes [DFAEKA] and [DFAEKB] and either of failure codes [DFAFKA] and [DFAFKB] occurred simultaneously. Action of controller • Limits operation of engine and transmission. Problem that appears on machine • Once machine is stopped, engine speed is limited to medium (half).
• Once machine is stopped, travel is limited to F1 and R1. Related information • State of ripper control lever tilt potentiometer signal can be checked with monitoring function. (Code: 73600 Ripper Tilt Lever A Potentio) (Code: 73601 Ripper Tilt Lever B Potentio) • Method of reproducing failure code: Turn starting switch ON + Operate ripper control lever (in tilting direction). Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting Carry out troubleshooting for failure codes [DFAEKA], [DFAEKB], [DFAFKA], and [DFAFKB]. Action code Failure code Trouble RL lever:
Disconnection or short circuit (Work equipment controller system) E03 DFADKZ Contents of trouble • In ripper control lever tilt potentiometer 1 and 2 systems, when starting switch is turned ON, only either side is abnormal and then either of failure codes [DFAEKA] and [DFAEKB] and either of fail- ure codes [DFAFKA] and [DFAFKB] occurred simultaneously. Action of controller • Limits operation of engine and transmission. Problem that appears on machine • Once machine is stopped, engine speed is limited to medium (half). • Once machine is stopped, travel is limited to F1 and R1.
Related information • State of ripper control lever tilt potentiometer signal can be checked with monitoring function. (Code: 73600 Ripper Tilt Lever A Potentio) (Code: 73601 Ripper Tilt Lever B Potentio) • Method of reproducing failure code: Turn starting switch ON + Operate ripper control lever (in tilting direction). Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting Carry out troubleshooting for failure codes [DFAEKA], [DFAEKB], [DFAFKA], and [DFAFKB].