SEN00720-01 40 Troubleshooting Failure code [DH21KA] Weq pressure sensor: Disconnection 1 48 D155AX-6 Action code Failure code Trouble Weq pressure sensor: Disconnection (Work equipment controller system) – DH21KA Contents of trouble • Signal voltage of work equipment pump oil pressure sensor is below 0.5 V. Action of controller • None in particular. Problem that appears on machine • Oil pressure of work equipment pump cannot be monitored. Related information • State of work equipment pump oil pressure sensor can be checked with monitoring function. (Code: 70701 Hydraulic Pressure Sensor 1) • Method of reproducing failure code: Turn starting switch ON.
Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective sensor 5V power supply system If failure code [DB95KK] is also displayed, carry out troubleshoot- ing for it first. 2 Defective work equipment oil pressure sensor (Internal trouble) a Prepare with starting switch OFF, then turn starting switch ON or start engine and carry out troubleshooting in each case. HHP Voltage Between (B) – (A) Power supply 4.5 – 5.5 V Between (C) – (A) Signal 0.5 – 6.0 V Sensor voltage is measured with wiring harness connected.
Accordingly, if voltage is abnormal, check wiring harness and con- troller, too, for another cause of trouble, and then judge. 3 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between WEC1 (female) (21) – HHP (female) (A) Resis- tance Max. 1 z Wiring harness between WEC3 (female) (34) – HHP (female) (B) Resis- tance Max. 1 z Wiring harness between WEC1 (female) (1) – HHP (female) (C) Resis- tance Max.
1 z 4 Ground fault in wiring har- ness (Contact with GND cir- cuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between WEC1 (female) (1) – HHP (female) (C) and chassis ground Resis- tance Min. 1 Mz 5 Defective work equipment controller If causes 1 – 4 are not detected, work equipment controller may be defective. (Since trouble is in system, troubleshooting cannot be carried out.)