Komatsu D155AX-6 — FAILURE CODE [DH21KB] WEQ PRESSURE SENSOR: SHORT CIRCUIT

SEN00720-01 40 Troubleshooting Failure code [DH21KB] Weq pressure sensor: Short circuit 1 50 D155AX-6 Action code Failure code Trouble Weq pressure sensor: Short circuit (Work equipment controller system) – DH21KB Contents of trouble • Signal voltage of work equipment pump oil pressure sensor is below 6.0 V. Action of controller • None in particular. Problem that appears on machine • Oil pressure of work equipment pump cannot be monitored. Related information • State of work equipment pump oil pressure sensor can be checked with monitoring function. (Code: 70701 Hydraulic Pressure Sensor 1) • Method of reproducing failure code: Turn starting switch ON.

Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective sensor 5V power supply system If failure code [DB95KK] is also displayed, carry out troubleshoot- ing for it first. 2 Defective work equipment oil pressure sensor (Internal trouble) a Prepare with starting switch OFF, then turn starting switch ON or start engine and carry out troubleshooting in each case. HHP Voltage Between (B) – (A) Power supply 4.5 – 5.5 V Between (C) – (A) Signal 0.5 – 6.0 V Sensor voltage is measured with wiring harness connected.

Accordingly, if voltage is abnormal, check wiring harness and con- troller, too, for another cause of trouble, and then judge. 3 Hot short (Short circuit with 24V circuit) in wiring harness a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. Wiring harness between WEC1 (female) (1) – HHP (female) (C) and chassis ground Voltage Max. 1 V 4 Defective work equipment controller If causes 1 – 3 are not detected, work equipment controller may be defective. (Since trouble is in system, troubleshooting cannot be carried out.)