SEN00720-01 40 Troubleshooting Failure code [DHT7KA] T/C out-pressure sensor: Disconnection 1 56 D155AX-6 Action code Failure code Trouble T/C out-pressure sensor: Disconnection (Power train controller system) E02 DHT7KA Contents of trouble • Signal voltage of torque converter outlet pressure sensor is below 0.5 V. Action of controller • Limits operation of engine and transmission. Problem that appears on machine • Torque converter outlet pressure cannot be monitored. • Once machine is stopped, engine speed is limited to medium (half). • Once machine is stopped, travel is limited to F1 and R1.
Related information • State of torque converter outlet pressure sensor can be checked with monitoring function. (Code: 32604 T/C Out Pressure Sensor) • Method of reproducing failure code: Turn starting switch ON. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective sensor 24 V power supply system If failure code [DBE6KK] is also displayed, carry out troubleshoot- ing for it first. 2 Defective torque converter outlet pressure sensor (Inter- nal trouble) a Prepare with starting switch OFF, then turn starting switch ON or start engine and carry out troubleshooting in each case.
TOP Voltage Between (B) – (A) Power supply 20 – 30 V Between (C) – (A) Signal 0.5 – 6.0 V Sensor voltage is measured with wiring harness connected. Accordingly, if voltage is abnormal, check wiring harness and con- troller, too, for another cause of trouble, and then judge. 3 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between STC1 (female) (21) – TOP (female) (A) Resis- tance Max. 1 z Wiring harness between STC1 (female) (16) – TOP (female) (B) Resis- tance Max.
1 z Wiring harness between STC1 (female) (14) – TOP (female) (C) Resis- tance Max. 1 z 4 Ground fault in wiring har- ness (Contact with GND cir- cuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between STC1 (female) (16) – TOP (female) (B) or circuit branch end Resis- tance Min. 1 Mz Wiring harness between STC1 (female) (14) – TOP (female) (C) and chassis ground Resis- tance Min. 1 Mz 5 Defective power train con- troller If causes 1 – 4 are not detected, power train controller may be defective. (Since trouble is in system, troubleshooting cannot be carried out.)