SEN00721-01 40 Troubleshooting Failure code [DK40KA] Brake potentiometer: Disconnection 1 14 D155AX-6 Action code Failure code Trouble Brake potentiometer: Disconnection (Power train controller system) E03 DK40KA Contents of trouble • Signal voltage of brake pedal potentiometer is below 0.5 V. Action of controller • Cannot recognize brake pedal position. Problem that appears on machine • Auto shift-down function may not operate normally. Related information • State of brake pedal potentiometer signal can be checked with monitoring function. (Code: 50400 Brake Pedal Potentio) • Method of reproducing failure code: Turn starting switch ON + Operate brake pedal.
Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective sensor 5V power supply system If failure code [DBE7KK] is also displayed, carry out troubleshoot- ing for it first. 2 Defective brake pedal poten- tiometer (Internal disconnec- tion) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON.
BRK (male) Resistance Between (A) – (C) 4.0 – 6.0 kz Between (A) – (B) 0.25 – 7.0 kz Between (B) – (C) 0.25 – 7.0 kz 3 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between STC1 (female) (21) – BRK (female) (A) Resis- tance Max. 1 z Wiring harness between STC1 (female) (3) – BRK (female) (B) Resis- tance Max. 1 z Wiring harness between STC1 (female) (22) – BRK (female) (C) Resis- tance Max.
1 z 4 Ground fault in wiring har- ness (Contact with GND cir- cuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between STC1 (female) (3) – BRK (female) (B) and chassis ground Resis- tance Min. 1 Mz Wiring harness between STC1 (female) (22) – BRK (female) (C) or circuit branch end and chassis ground Resis- tance Min. 1 Mz 5 Defective power train con- troller a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. STC1 Voltage Between (3) – (21) 0.5 – 4.5 V