Komatsu D155AX-6 — FAILURE CODE [DB40KB] BRAKE POTENTIOMETER: SHORT CIRCUIT

SEN00721-01 40 Troubleshooting Failure code [DK40KB] Brake potentiometer: Short circuit 1 16 D155AX-6 Action code Failure code Trouble Brake potentiometer: Short circuit (Power train controller system) E03 DK40KB Contents of trouble • Signal voltage of brake pedal potentiometer is above 4.5 V. Action of controller • Cannot recognize brake pedal position. Problem that appears on machine • Auto shift-down function may not operate normally. Related information • State of brake pedal potentiometer signal can be checked with monitoring function. (Code: 50400 Brake Pedal Potentio) • Method of reproducing failure code: Turn starting switch ON + Operate brake pedal.

Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective sensor 5V power supply system If failure code [DBE7KK] is also displayed, carry out troubleshoot- ing for it first. 2 Defective brake pedal poten- tiometer (Internal short cir- cuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. BRK (male) Resistance Between (A) – (C) 4.0 – 6.0 kz Between (A) – (B) 0.25 – 7.0 kz Between (B) – (C) 0.25 – 7.0 kz 3 Hot short (Short circuit with 24V circuit) in wiring harness a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting.

Wiring harness between STC1 (female) (3) – BRK (female) (B) and chassis ground Voltage Max. 1 V Wiring harness between STC1 (female) (22) – BRK (female) (C) or circuit branch end and chassis ground Voltage Max. 1 V 4 Defective power train con- troller a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. STC1 Voltage Between (3) – (21) 0.5 – 4.5 V