Komatsu D155AX-6 — FAILURE CODE [DK55L8] FR LEVER: SIGNAL MISMATCH

40 Troubleshooting SEN00721-01 Failure code [DK55L8] FR lever: Signal mismatch 1 D155AX-6 19 Action code Failure code Trouble FR lever: Signal mismatch (Power train controller system) E03 DK55L8 Contents of trouble • In PCCS lever F-R potentiometer 1 and 2 systems, total of both signal voltages is below 4.41 V or above 5.59 V. Action of controller • Continues control with signal of normal one of PCCS lever F-R potentiometer 1 and 2 systems. • Limits operation of engine and transmission. Problem that appears on machine • Once machine is stopped, engine speed is limited to medium (half). • Once machine is stopped, travel is limited to F1 and R1.

Related information • State of PCCS lever F-R potentiometer signal can be checked with monitoring function. (Code: 50200 T/M Lever 1 Potentio) (Code: 50201 T/M Lever 2 Potentio) • Method of reproducing failure code: Turn starting switch ON + Operate PCCS lever (in F-R direc- tion). Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting Carry out troubleshooting for failure codes [DK56KA], [DK56KB], [DK57KA], and [DK57KB].