Komatsu D155AX-6 — FAILURE CODE [DK56KB] FR LEVER 1: SHORT CIRCUIT

SEN00721-01 40 Troubleshooting Failure code [DK56KB] FR lever 1: Short circuit 1 22 D155AX-6 Action code Failure code Trouble FR lever 1: Short circuit (Power train controller system) E03 DK56KB Contents of trouble • Signal voltage of PCCS lever F-R potentiometer 1 system is above 4.5 V. Action of controller • Continues control with signal of PCCS lever F-R potentiometer 2 system. • Limits operation of engine and transmission. Problem that appears on machine • Once machine is stopped, engine speed is limited to medium (half). • Once machine is stopped, travel is limited to F1 and R1. Related information • State of PCCS lever F-R potentiometer 1 signal can be checked with monitoring function.

(Code: 50200 T/M Lever 1 Potentio) • Method of reproducing failure code: Turn starting switch ON + Operate PCCS lever (in F-R direc- tion). Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective sensor 5V power supply system If failure code [DBE7KK] is also displayed, carry out troubleshoot- ing for it first. 2 Defective PCCS lever F-R potentiometer 1 (Internal short circuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON.

TLV1 (male) PCCS lever Resistance Between (4) – (1) Neutral 3.2 kz ± 20% Between (4) – (3) 1.6 kz ± 20% Between (3) – (1) 1.6 kz ± 20% 3 Hot short (Short circuit with 24V circuit) in wiring harness a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. Wiring harness between STC1 (female) (13) – TLV1 (female) (3) and chassis ground Voltage Max. 1 V 4 Defective power train con- troller a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. STC1 Voltage Between (13) – (21) 0.5 – 4.5 V