SEN00721-01 40 Troubleshooting Failure code [DKH1KB] Pitch angle sensor: Short circuit 1 30 D155AX-6 Action code Failure code Trouble Pitch angle sensor: Short circuit (Power train controller system) E03 DKH1KB Contents of trouble • Signal voltage of pitch angle sensor is above 4.85 V. Action of controller • Cannot sense pitch angle of machine. • Limits operation of engine and transmission. Problem that appears on machine • Gearshift shock is made on slope or steering shock is made on level ground. • Once machine is stopped, engine speed is limited to medium (half). • Once machine is stopped, travel is limited to F1 and R1.
Related information • State of pitch angle sensor signal can be checked with monitoring function. (Code: 60100 Pitch Angle Sensor) • Method of reproducing failure code: Turn starting switch ON. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective sensor 24V power supply system If failure code [DBE6KK] is also displayed, carry out troubleshoot- ing for it first. 2 Defective pitch angle sensor (Internal trouble) a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting.
PT1 Voltage Between (C) – (A) Power supply 20 – 30 V Between (B) – (A) Signal 0.15 – 4.85 V Sensor voltage is measured with wiring harness connected. Accordingly, if voltage is abnormal, check wiring harness and con- troller, too, for another cause of trouble, and then judge. 3 Hot short (Short circuit with 24V circuit) in wiring harness a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. Wiring harness between STC1 (female) (8) – PT1 (female) (B) and chassis ground Voltage Max. 1 V 4 Defective power train con- troller If causes 1 – 3 are not detected, power train controller may be defective.
(Since trouble is in system, troubleshooting cannot be carried out.)