SEN00721-01 40 Troubleshooting Failure code [DWN3KA] Ssp solenoid: Disconnection 1 42 D155AX-6 Action code Failure code Trouble Ssp solenoid: Disconnection (Power train controller system) E04 DWN3KA Contents of trouble • When signal is output to sudden stop prevent solenoid circuit, no current flows. Action of controller • Limits operation of engine, transmission, and brake. Problem that appears on machine • Brake is applied lightly during travel. • Once machine is stopped, engine speed is limited to medium (half). • Once machine is stopped, it cannot travel at all. Related information • Output to sudden stop prevent solenoid can be checked with monitoring function. (Code:
31628 SSP Solenoid) • Method of reproducing failure code: Turn starting switch ON. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective sudden stop pre- vent solenoid (Internal dis- connection) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. SSP (male) Resistance Between (1) – (2) 3.5 – 12.5 z 2 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON.
Wiring harness between STC3 (female) (7) – SSP (female) (1) Resis- tance Max. 1 z Wiring harness between STC3 (female) (23) – SSP (female) (2) Resis- tance Max. 1 z 3 Hot short (Short circuit with 24V circuit) in wiring harness a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. Wiring harness between STC3 (female) (7) – SSP (female) (1) and chassis ground Voltage Max. 1 V 4 Defective power train con- troller a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. STC3 (female) Resistance Between (7) – (23) 3.5 – 12.5 z