Komatsu D155AX-6 — FAILURE CODE [DWN3KB] SSP SOLENOID: SHORT CIRCUIT

SEN00721-01 40 Troubleshooting Failure code [DWN3KB] Ssp solenoid: Short circuit 1 44 D155AX-6 Action code Failure code Trouble Ssp solenoid: Short circuit (Power train controller system) E04 DWN3KB Contents of trouble • When signal was output to sudden stop prevent solenoid circuit, abnormal current flowed. Action of controller • Limits operation of engine, transmission, and brake. Problem that appears on machine • Brake is applied lightly during travel. • Once machine is stopped, engine speed is limited to medium (half). • Once machine is stopped, it cannot travel at all. Related information • Output to sudden stop prevent solenoid can be checked with monitoring function. (Code:

31628 SSP Solenoid) • Method of reproducing failure code: Turn starting switch ON. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective sudden stop pre- vent solenoid (Internal short circuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. SSP (male) Resistance Between (1) – (2) 3.5 – 12.5 z Between (1) – chassis ground Min. 1 Mz 2 Ground fault in wiring har- ness (Contact with GND cir- cuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON.

Wiring harness between STC3 (female) (7) – SSP (female) (1) and chassis ground Resis- tance Min. 1 Mz 3 Short circuit in wiring har- ness (with another wiring harness) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between STC3 (female) (7) – SSP (female) (1) and between STC3 (female) (23) – SSP (female) (2) Resis- tance Min. 1 Mz 4 Defective power train con- troller a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. STC3 (female) Resistance Between (7) – (23) 3.5 – 12.5 z Between (7) – chassis ground Min. 1 Mz