SEN00721-01 40 Troubleshooting Failure code [DXH1KB] Lock-up ECMV: Short circuit 1 56 D155AX-6 Action code Failure code Trouble Lock-up ECMV: Short circuit (Power train controller system) E02 DXH1KB Contents of trouble • When signal was output to torque converter lockup clutch ECMV solenoid circuit, abnormal current flowed. Action of controller • Turns signal to torque converter lockup clutch ECMV solenoid circuit OFF. Problem that appears on machine • Torque converter lockup function does not operate. Related information • Output to torque converter lockup clutch ECMV solenoid can be checked with monitoring function. (Code: 31642 L/U ECMV (F/B)) • Method of reproducing failure code:
Start engine + Drive forward (in auto gearshift mode). Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective lockup clutch ECMV solenoid (Internal short circuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. SLUC (male) Resistance Between (1) – (2) 3.5 – 12.5 z Between (1) – chassis ground Min. 1 Mz 2 Ground fault in wiring har- ness (Contact with GND cir- cuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between STC3 (female) (17) – SLUC (female) (1) and chassis ground Resis- tance Min.
1 Mz 3 Short circuit in wiring har- ness (with another wiring harness) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between STC3 (female) (17) – SLUC (female) (1) and between STC3 (female) (13) – SLUC (female) (2) Resis- tance Min. 1 Mz 4 Defective power train con- troller a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. STC3 (female) Resistance Between (17) – (13) 3.5 – 12.5 z Between (17) – chassis ground Min. 1 Mz