Komatsu D155AX-6 — FAILURE CODE [DXHCKB] LEFT BRAKE ECMV: SHORT CIRCUIT

SEN00722-01 40 Troubleshooting Failure code [DXHCKB] Left brake ECMV: Short circuit 1 26 D155AX-6 Action code Failure code Trouble Left brake ECMV: Short circuit (Power train controller system) E04 DXHCKB Contents of trouble • When signal was output to steering case left brake ECMV solenoid circuit, abnormal current flowed. Action of controller • Turns signal to steering case left brake ECMV solenoid circuit OFF. • Limits operation of engine and transmission. Problem that appears on machine • Brake is applied lightly during travel. • Once machine is stopped, engine speed is limited to medium (half). • Once machine is stopped, it cannot travel at all.

Related information • Output to left brake ECMV solenoid can be checked with monitoring function. (Code: 31619 Brake LH ECMV (F/B)) • Method of reproducing failure code: Turn starting switch ON + Operate parking brake lever (Free). Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective left brake ECMV solenoid (Internal short cir- cuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. SBRL (male) Resistance Between (1) – (2) 3.5 – 12.5 z Between (1) – chassis ground Min.

1 Mz 2 Ground fault in wiring har- ness (Contact with GND cir- cuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between STC3 (female) (5) – SBRL (female) (1) and chassis ground Resis- tance Min. 1 Mz 3 Short circuit in wiring har- ness (with another wiring harness) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between STC3 (female) (5) – SBRL (female) (1) and between STC3 (female) (3) – SBRL (female) (2) Resis- tance Min.

1 Mz 4 Defective power train con- troller a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. STC3 (female) Resistance Between (5) – (3) 3.5 – 12.5 z Between (5) – chassis ground Min. 1 Mz