Komatsu D155AX-6 — FAILURE CODE [DXHSKY] BLADE DOWN EPC: SHORT CIRCUIT

40 Troubleshooting SEN00722-01 Failure code [DXHSKY] Blade down EPC: Short circuit 1 Circuit diagram related to blade lift-down EPC solenoid D155AX-6 35 Action co de Failure code Trouble Blade down EPC: Short circuit (Work equipment controller system) E03 DXHSKY Contents trouble of • When signal was output to blade lift-down EPC solenoid circuit, abnormal current flowed. Action o controlle f • Turns signal to blade lift-down EPC solenoid circuit OFF. r • Limits operation of engine and transmission. Problem t appears machin hat • Blade cannot be lifted down. on • Once machine is stopped, engine speed is limited to medium (half). e • Once machine is stopped, travel is limited to R1.

Related informati • Output to blade lift-down EPC solenoid can be checked with monitoring function. (Code: 71003 Blade Down EPC (F/B)) on • Method of reproducing failure code: Turn starting switch ON + Operate blade control lever (Lower). Possible ca and stand value in no state Cause Defective blade lift-down 1 EPC solenoid (Internal short circuit) uses ard Hot short (Short circuit with rmal 2 24V circuit) in wiring harness Defective work equipment 3 controller Standard value in normal state/Remarks on troubleshooting Defective blade lift-down EPC solenoid (Internal short circuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON.

WEP2 (male) Resistance Between (1) – (2) 4.5 – 14.5 z Between (1) – chassis ground Min. 1 Mz Hot short (Short circuit with 24V circuit) in wiring harness a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. Wiring harness between WEC3 (female) (16) – WEP2 (female) (1) and chassis ground Voltage Max. 1 V Defective work equipment controller a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. WEC3 (female) Resistance Between (16) – (13) 4.5 – 14.5 z Between (16) – chassis ground Min. 1 Mz