Komatsu D155AX-6 — FAILURE CODE [DXHUKA] BLADE RIGHT 1 EPC: DISCONNECTION

40 Troubleshooting SEN00722-01 Failure code [DXHUKA] Blade right 1 EPC: Disconnection 1 Circuit diagram related to blade tilt right bottom EPC solenoid D155AX-6 39 Action cod e Failure code Trouble Blade right 1 EPC: Disconnection (Work equipment controller system) E03 DXHUKA Contents o trouble f • When signal is output to blade tilt right bottom EPC solenoid circuit, no current flows. Action of controller • Turns signal to blade tilt right bottom EPC solenoid circuit OFF. • Limits operation of engine and transmission. Problem tha appears on machine t • Blade tilt cylinder or pitch right cylinder cannot be retracted. • Once machine is stopped, engine speed is limited to medium (half).

• Once machine is stopped, travel is limited to R1. Related information • Output to blade tilt right bottom EPC solenoid can be checked with monitoring function. (Code: 90801 Blade Tilt RH-B EPC (F/B)) • Method of reproducing failure code: Turn starting switch ON + Operate blade control lever (Pitch forward).

Possible caus and standar value in norm state Cause Defective blade tilt right bot- 1 tom EPC solenoid (Internal disconnection) es Disconnection in wiring har- d ness (Disconnection in wiring al 2 or defective contact in con- nector) Defective work equipment 3 controller Standard value in normal state/Remarks on troubleshooting a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. WEP6 (male) Resistance Between (1) – (2) 2 – 12 z a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between WEC3 (female) (36) – WEP6 (female) (1) Resis- M tance ax.

1 z Wiring harness between WEC3 (female) (23) – WEP6 (female) (2) Resis- M tance ax. 1 z a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. WEC3 (female) Resistance Between (36) – (23) 2 – 12 z