40 Troubleshooting SEN00722-01 Failure code [DXHWKB] Ripper up EPC: Short circuit 1 Circuit diagram related to ripper lift-up EPC solenoid D155AX-6 43 Action code Failure code Trouble Ripper up EPC: Short circuit (Work equipment controller system) E03 DXHWKB Contents o trouble f • When signal was output to ripper lift-up EPC solenoid circuit, abnormal current flowed. Action of controller • Turns signal to ripper lift-up EPC solenoid circuit OFF. • Limits operation of engine and transmission. Problem tha appears on machine t • Ripper cannot be lifted up. • Once machine is stopped, engine speed is limited to medium (half). • Once machine is stopped, travel is limited to R1.
Related information • Output to ripper lift-up EPC solenoid can be checked with monitoring function. (Code: 71101 Ripper Raise EPC (F/B)) • Method of reproducing failure code: Turn starting switch ON + Operate ripper control lever (Raise). Possible caus and standar value in norm state Cause Defective ripper lift-up EPC 1 solenoid (Internal short cir- cuit) es d Ground fault in wiring har- al 2 ness (Contact with GND cir- cuit) Defective work equipment 3 controller Standard value in normal state/Remarks on troubleshooting a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON.
WEP7 (male) Resistance Between (1) – (2) 2 – 12 z Between (1) – chassis ground Min. 1 Mz a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between WEC3 (female) (5) – WEP7 (female) (1) and chassis ground Resis- Min tance . 1 Mz a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. WEC3 (female) Resistance Between (5) – (23) 2 – 12 z Between (5) – chassis ground Min. 1 Mz