SEN00723-01 40 Troubleshooting Failure code [DXJAKY] Q-drop EPC: Short circuit 1 12 D155AX-6 Action code Failure code Trouble Q-drop EPC: Short circuit (Work equipment controller system) E01 DXJAKY Contents of trouble • When signal was output to blade quick drop EPC solenoid circuit, abnormal current flowed. Action of controller • Turns signal to blade quick drop EPC solenoid circuit OFF. Problem that appears on machine • Blade quick drop function does not operate. Related information • Output to blade quick drop EPC solenoid can be checked with monitoring function. (Code: 90900 Quick Drop Solenoid (F/B)) • Method of reproducing failure code:
Turn starting switch ON + Operate blade control lever (Lower). Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective blade quick drop EPC solenoid (Internal short circuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. QDP (male) Resistance Between (1) – (2) 4.5 – 14.5 z Between (1) – chassis ground Min. 1 Mz 2 Hot short (Short circuit with 24V circuit) in wiring harness a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. Wiring harness between WEC3 (female) (37) – QDP (female) (1) and chassis ground Voltage Max.
1 V 3 Defective work equipment controller a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. WEC3 (female) Resistance Between (37) – (3) 4.5 – 14.5 z Between (37) – chassis ground Min. 1 Mz