SEN00723-01 40 Troubleshooting Failure code [DXJBKA] S/C ECMV: Disconnection 1 14 D155AX-6 Action code Failure code Trouble S/C ECMV: Disconnection (Power train controller system) E02 DXJBKA Contents of trouble • When signal is output to torque converter stator clutch ECMV solenoid circuit, no current flows. Action of controller • Turns signal to torque converter stator clutch ECMV solenoid circuit OFF. Problem that appears on machine • Sufficient torque may not be obtained during travel. Related information • Output to torque converter stator clutch ECMV solenoid can be checked with monitoring function. (Code: 90700 S/C ECMV (F/B)) • Method of reproducing failure code:
Turn starting switch ON + Operate parking brake lever (Free). Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective stator clutch ECMV solenoid (Internal disconnec- tion) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. SSTC (male) Resistance Between (1) – (2) 5 – 25 z 2 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between STC3 (female) (38) – SSTC (female) (1) Resis- tance Max.
1 z Wiring harness between STC3 (female) (13) – SSTC (female) (2) Resis- tance Max. 1 z 3 Hot short (Short circuit with 24V circuit) in wiring harness a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. Wiring harness between STC3 (female) (38) – SSTC (female) (1) and chassis ground Voltage Max. 1 V 4 Defective power train con- troller a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. STC3 (female) Resistance Between (38) – (13) 5 – 25 z