SEN00723-01 40 Troubleshooting Failure code [DXJBKB] S/C ECMV: Short circuit 1 16 D155AX-6 Action code Failure code Trouble S/C ECMV: Short circuit (Power train controller system) E02 DXJBKB Contents of trouble • When signal was output to torque converter stator clutch ECMV solenoid circuit, abnormal current flowed. Action of controller • Turns signal to torque converter stator clutch ECMV solenoid circuit OFF. Problem that appears on machine • Sufficient torque may not be obtained during travel. Related information • Output to torque converter stator clutch ECMV solenoid can be checked with monitoring function. (Code: 90700 S/C ECMV (F/B)) • Method of reproducing failure code:
Turn starting switch ON + Operate parking brake lever (Free). Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective stator clutch ECMV solenoid (Internal short cir- cuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. SSTC (male) Resistance Between (1) – (2) 5 – 25 z Between (1) – chassis ground Min. 1 Mz 2 Ground fault in wiring har- ness (Contact with GND cir- cuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON.
Wiring harness between STC3 (female) (38) – SSTC (female) (1) and chassis ground Resis- tance Min. 1 Mz 3 Short circuit in wiring har- ness (with another wiring harness) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between STC3 (female) (38) – SSTC (female) (1) and between STC3 (female) (13) – SSTC (female) (2) Resis- tance Min. 1 Mz 4 Defective power train con- troller a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. STC3 (female) Resistance Between (38) – (13) 5 – 25 z Between (38) – chassis ground Min. 1 Mz