40 Troubleshooting SEN00807-01 Troubleshooting of electrical system (E-mode) 1 Before carrying out troubleshooting for electrical system 1 Connection table of circuit breakers and fuse boxes a This connection table shows the devices to which each power supply of the fuse box supplies power (An accessory power supply is a device which supplies power while the starting switch is in the ON position and an unswitched power supply is a device which supplies power while the starting switch is in the OFF and ON positions). a When carrying out troubleshooting related to the electrical system, you should check the circuit breakers and fuses to see if the power is supplied normally.
Circuit breakers CB1 – CB9 Fuse box FS1 D155AX-6 3 Power circuit breaker (Type of power supply) Circuit breaker No.
Circuit breaker capacity Destination of power CB105 (Accessory power supply) CB9 20A Optional power supply CB1 20A Power train controller Emergency power supply (For power train switch box) CB2 20A Work equipment controller Emergency power supply (For work equipment switch box) CB3 20A Air conditioner unit, blower motor, and compressor electromag- netic clutch CB4 20A Headlamp, additional headlamp CB5 20A Rear lamp, additional rear lamp, ripper point lamp CB30 (Unswitched power supply) CB6 20A Starting switch Engine hold relay CB7 20A Machine monitor Power train controller Work equipment controller CB8 30A Engine controller CB105H (Unswitched power supply) — — Engine electrical intake air heater Power circuit breaker (Type of power supply) Fuse No.
Fuel capacity Destination of power CB30 (Unswitched power supply) 1 20A Operator's cab power supply (To connection table of fuse box ) CB105 (Accessory power supply) 2 5A Backup alarm, backup alarm relay 3 20A Operator's cab power supply (To connection table of fuse box ) 4 20A Operator's cab power supply (To connection table of fuse box ) Starting switch (ACC) 5 5A Engine controller (Signal ACC)