Komatsu D155AX-6 — E-1 WHEN STARTING SWITCH TURNED ON, MACHINE MONITOR DISPLAYS NOTHING

40 Troubleshooting SEN00807-01 Circuit diagram related to machine monitor power supply D155AX-6 9 Possible ca and stand value in no state Cause Ground fault in wiring har- 6 ness (Contact with GND cir- cuit) uses ard rmal 7 Defective machine monitor Standard value in normal state/Remarks on troubleshooting a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between battery (+) – termi- Resis- Min. 1 Mz nal BRB – CB30 (B30L) and chassis ground tance Wiring harness between CB30 (B30S) – Resis- CB7 (1) or circuit branch end and chassis Min.

1 Mz tance ground Wiring harness between CB7 (2) – CM01 Resis- (female) (1), (2) or circuit branch end and Min. 1 Mz tance chassis ground Wiring harness between CB30 (B30S) – Resis- CB6 (1) or circuit branch end and chassis Min. 1 Mz tance ground Wiring harness between CB6 (2) – terminal Resis- 250 or circuit branch end and chassis Min. 1 Mz tance ground Wiring harness between terminal 270 – Resis- CM01 (female) (14) or circuit branch end Min. 1 Mz tance and chassis ground Resis- Min. 1 Mz tance Resis- Min. 1 Mz tance Resis- Min. 1 Mz tance Resis- Min. 1 Mz tance Resis- Min. 1 Mz tance Resis- Min.

1 Mz tance a Prepare with starting switch OFF, then hold starting switch OFF and ON and carry out troubleshooting in each case. CM01 Starting switch Voltage Between (1), (2) – OFF 20 – 30 V (3) , (4) Between (14) – ON 20 – 30 V (3), (4) Starting switch Voltage ) – OFF 20 – 30 V – ON 20 – 30 V