Komatsu D155AX-6 — E-5 PRECAUTION ITEM LIGHTS UP WHILE ENGINE IS RUNNING

SEN00807-01 40 Troubleshooting E-5 Precaution item lights up while engine is running 1 18 D155AX-6 Trouble • Precaution item lights up while engine is running. Related information • Check item is only charge level monitor. • State of generation signal of alternator can be checked with monitoring function. (Code: 04300 Battery Charge Volt) Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective generation by alternator (when system is normal) a Prepare with starting switch OFF, then start engine and carry out troubleshooting.

Alternator Engine speed Voltage Between R – chassis ground Medium or higher 20 – 30 V 2 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between CM01 (female) (11) – terminal R Resis- tance Max. 1 z 3 Ground fault in wiring har- ness (Contact with GND cir- cuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between CM01 (female) (11) – terminal R or circuit branch end and chas- sis ground Resis- tance Min.