Komatsu D155AX-6 — E-10 HYDRAULIC TEMPERATURE GAUGE (MULTI-GAUGE) DOES NOT INDICATE NORMALLY

SEN00807-01 40 Troubleshooting E-10 Hydraulic temperature gauge (multi-gauge) does not indicate normally 1 26 D155AX-6 Trouble (1) While hydraulic oil temperature is rising normally, temperature gauge does not rise from white range (C). (2) While hydraulic oil temperature is stabilized normally, temperature gauge rises to red range (H). Related information • Hydraulic temperature can be checked with monitoring function. (Code:

04401 Hyd Oil Temperature) Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective hydraulic oil tem- perature sensor system (Internal disconnection or short circuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. HDT (male) Resistance Between (1) – (2) 3.5 – 90 kz Between (2) – chassis ground Min. 1 Mz 2 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON.

Wiring harness between CM01 (female) (8) – HDT (female) (1) Resis- tance Max. 1 z Wiring harness between CM01 (female) (12) – HDT (female) (2) Resis- tance Max. 1 z 3 Ground fault in wiring har- ness (Contact with GND cir- cuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between CM01 (female) (8) – HDT (female) (1) and chassis ground Resis- tance Min. 1 Mz 4 Hot short (Short circuit with 24V circuit) in wiring harness a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. Wiring harness between CM01 (female) (8) – HDT (female) (1) and chassis ground Voltage Max.

1 V 5 Defective machine monitor If causes 1 – 4 are not detected, machine monitor may be defec- tive. (Since trouble is in system, troubleshooting cannot be carried out.)