Komatsu D155AX-6 — E-13 FUNCTION SWITCH DOES NOT WORK

40 Troubleshooting SEN00807-01 E-11 Contents of display by machine monitor are different from applicable machine 1 E-12 Machine monitor does not display some items 1 E-13 Function switch does not work 1 D155AX-6 29 Trouble • Contents of display by machine monitor are different from applicable machine. Related information Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective machine monitor Machine monitor may be defective. (Since trouble is in system, troubleshooting cannot be carried out.) Trouble • Machine monitor does not display some items.

Related information • The LCD panel sometimes has black points (points which are not lighted) and bright points (points which do not go off) for the reason of its characteristics. If the number of the bright points and black points does not exceed 10, those points are not a failure or a defect. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective machine monitor (LCD panel) a Turn starting switch ON and carry out troubleshooting. When following switches are operated, if all LCD panel is lighted up (all surface becomes white), LCD panel is normal. • Operation of switches:

[4] + [F2] (Press simultaneously) 2 Defective machine monitor (body) If cause 1 is not detected, machine monitor may be defective. (Since trouble is in system, troubleshooting cannot be carried out.) Trouble • Function switch does not work. Related information Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective machine monitor Machine monitor may be defective. (Since trouble is in system, troubleshooting cannot be carried out.)