SEN00807-01 40 Troubleshooting 40 D155AX-6 Trouble (10) Air conditioner fault history: Daylight sensor "Abnormality" Related information • If "CAN disconnection" is displayed as communication condition, communication cannot be carried out normally. Accordingly, this condition is not displayed. • Method of reproducing fault history: Turn starting switch ON + Turn air conditioner (A/C) switch ON. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective daylight sensor (Internal defect) Daylight sensor may be defective.
2 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between ACW (wiring side) (3) – SLS (female) (1) Resis- tance Max. 1 z Wiring harness between ACW (wiring side) (15) – SLS (female) (2) Resis- tance Max. 1 z 3 Ground fault in wiring har- ness (Contact with GND cir- cuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between ACW (wiring side) (3) – SLS (female) (1) or circuit branch end and chassis ground Resis- tance Min.
1 Mz Wiring harness between ACW (wiring side) (15) – SLS (female) (2) and chassis ground Resis- tance Min. 1 Mz 4 Hot short (Short circuit with 24V circuit) in wiring harness a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. Wiring harness between ACW (wiring side) (3) – SLS (female) (1) or circuit branch end and chassis ground Voltage Max. 1 V Wiring harness between ACW (wiring side) (15) – SLS (female) (2) and chassis ground Voltage Max. 1 V 5 Defective air conditioner con- troller If causes 1 – 4 are not detected, air conditioner controller may be defective. (Since trouble is in system, troubleshooting cannot be carried out.)