40 Troubleshooting SEN00807-01 D155AX-6 43 Trouble (13) Air conditioner fault history: Refrigerant "Abnormality" Related information • If "CAN disconnection" is displayed as communication condition, communication cannot be carried out normally. Accordingly, this condition is not displayed. • Method of reproducing fault history: Turn starting switch ON + Turn air conditioner (A/C) switch ON. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Insufficient refrigerant (gas) (when system is normal) Refrigerant (gas) may be insufficient. Check it directly.
2 Defective high and low pres- sure switches (Internal dis- connection) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. AC05 (male) Resistance Between (1) – (2) Max. 1 z 3 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between ACW (wiring side) (4) – AC05 (female) (1) Resis- tance Max. 1 z Wiring harness between AC05 (female) (2) – chassis ground (GND12) Resis- tance Max.
1 z 4 Defective air conditioner con- troller If causes 1 – 3 are not detected, air conditioner controller may be defective. (Since trouble is in system, troubleshooting cannot be carried out.)