Komatsu — REPLACING ADDITIONAL FILTER ELEMENT FOR BREAKER (IF EQUIPPED)

MAINTENANCE MAINTENANCE INTERVAL FOR HYDRAULIC BREAKER For machine equipped with a hydraulic breaker, the hydraulic oil deteriorates faster than for normal bucket digging operations, so set the maintenance intervals as follows. REPLACE HYDRAULIC FILTER ELEMENT On a new machine, replace the element after the first 100 to 150 hours, then carry out further replacement of the element according to the table on the right. CHANGE OIL IN HYDRAULIC TANK Change the oil according to the table on the right. REPLACING ADDITIONAL FILTER ELEMENT FOR BREAKER (IF EQUIPPED) Use a guideline of 250 hours for use of the breaker (operating ratio for the breaker:

50% or more), and replace the element according to the table on the right. X : Breaker operating ratio (%) Y : Replacement interval (H) ( A ): Hydraulic filter element ( B ): Hydraulic oil ( C ): Additional filter element Remark Breaker operating ratio 100% means that only the breaker is used Breaker operating ratio 0% means that the breaker is not used 3-18 PC300LC/HD-7E0