Komatsu — CHECK, CLEAN AND REPLACE AIR CLEANER ELEMENT

MAINTENANCE 7. If small holes or thinner parts are found on the element when it is checked by shining a light through it after cleaning, replace the element. 8. Remove the cloth or tape covering inner element (6). Do not use an element whose folds or gasket or seal are damaged. If the element or O-ring are cleaned and used again after they have been used for more than one year, it will cause problems. Do not use them again. 9. Check to be sure there is no dirt or oil stuck to the seal portion of the new element or cleaned element. Wipe off any dirt or oil. 10. Push the outer element in straight with your hand when installing it to the air cleaner body.

If the outer element is held and rocked lightly up and down and to the left and right while pushing it in, the outer element can be inserted easily. When inserting the element, if the rubber at the tip is swollen or the outer element is not pushed in straight, and cover (3) is assembled by force to hook (2), there is danger that the hook and air cleaner body may be damaged, so be careful when assembling. 11. Install cover (3) as follows. A. Align cover (3) with the element. B. Hook the tip of hook (2) to the protruding part of the air cleaner body and lock it in position. C.

When locking hooks (2) in position, apply the hooks in turn on opposite sides (top, bottom, left, right) in the same way as when tightening bolts. D. Always install cover (3) so that the evacuator (4) is facing the ground (A). E. When cover (3) is installed, check to be sure the clearance between the air cleaner body and cover (3) is not too large. F. If it is too large, install again. REPLACING ELEMENT 1. Open the right door of the machine, remove 6 hooks (2), then remove cover (3). 3-22 PC300LC/HD-7E0