Komatsu — BREAKER CIRCUIT ADDITIONAL OIL FILTER

OPTIONS, ATTACHMENTS ACCUMULATOR The accumulator is charged with high-pressure nitrogen gas, improper operation may cause an explosion which could lead to serious injury or damage. When handling the accumulator, always do as follows: Pressure in the control circuit cannot be completely removed. When removing the hydraulic equipment, do not stand in the direction that oil spurts out when performing the operation. Loosen the bolts slowly. Do not disassemble the accumulator. Do not bring it near flame or dispose of it in fire. Do not make holes in it or weld it. Do not hit it, roll it, or subject it to any impact. When disposing of the accumulator, the gas must be released.

Contact your Komatsu distributor for proper disposal, see “ACCUMULATOR” on page 1-36 Accumulator (6) is installed to reduce the peak pressure in the hydraulic circuit when a breaker is used. Normally, do not touch it. On machines equipped with a breaker, it is necessary to install an accumulator to the breaker piping to match the model number of the breaker manufacturer. If no accumulator is installed and the breaker is operated, the service life of the machine will be reduced. For questions about the breaker, please contact your Komatsu distributor.

If the pressure of the nitrogen gas charging the accumulator drops, it will be impossible to release the remaining pressure in the control circuit after the engine is stopped. In addition, if operations are continued with the nitrogen gas at low pressure, it will cause damage to the hydraulic circuit or machine. Check the nitrogen charge pressure periodically BREAKER CIRCUIT ADDITIONAL OIL FILTER This filter (5) prevents deterioration of the hydraulic oil when using a breaker. Oil only flows when B mode is selected on the monitor. Always install an additional filter in the return circuit on machines equipped with a hydraulic breaker. PC300LC/HD-7E0 5-7