MAN — Man EPA07 MBE 4000 Engine Operator's Manual

ENGINE STORAGE or higher. Charge the battery, if necessary. NOTE: The small amount of rust preventive which remains in the fuel system will cause smoky exhaust for a few minutes. 10. Service the air cleaner, if required. 11. Transmission: Follow the manufacturer's recommendations covering the return of the transmission to service. NOTE: Before subjecting the engine to a load or high speed, allow it to reach normal operating temperature. Then check for trouble codes. 12. Power Take-Off: If equipped, follow the manufacturer's recommendations covering the return of the power take-off to service. 13. Turbocharger: Remove the covers from the turbocharger air inlet and turbine outlet connections.

Reconnect piping as required. Prelube the turbocharger center bearing housing. Refer to “Lubrication System Checks” in the “OPERATING INSTRUCTIONS FOR STARTING THE ENGINE” section of this guide. ENGINE EXHAUST To avoid injury from inhaling engine exhaust, always operate the engine in a well-ventilated area. Engine exhaust is toxic. 14. After all preparations are completed, start the engine. 136 All information subject to change without notice. DDC-SVC-MAN-0041 Copyright © 2009 DETROIT DIESEL CORPORATION