OPERATING INSTRUCTIONS FOR STARTING THE ENGINE Emergency Running Mode For fault codes and their meanings, see the DDEC VI MBE 4000 Troubleshooting Guide (6SE568). The engine is equipped with the electronic engine control system, which monitors the engine as it is running. Stop Engine Override Option As soon as a fault is detected, it is evaluated and one of the following measures is initiated. The Stop Engine Override Option is used for a momentary override. The Motor Control Module (MCM) will record the number of times the override is activated after a fault occurs. NOTICE: To prevent possible serious engine damage, have any faults corrected without delay by an authorized dealer.
Momentary Override A Stop Engine Override (SEO) switch is used to override the shutdown sequence (see Figure 15). This override resets the 60 second (30 seconds for oil pressure) shutdown timer, restoring power to the level when the RSL (Stop Engine) was illuminated. The switch must be recycled after five seconds to obtain a subsequent override. In conjunction with any dashboard or instrument panel display, the code for the electronic control unit reporting the fault can be read immediately on the display. Complete fault codes are transmitted and can be read using DDDL 7.0 or latest version.
If the fault is serious enough to impair normal operation, the electronic engine system switches over to emergency running mode. When in emergency running mode, the engine operates at a constant 1300 rpm. This allows you to move the vehicle to a service location. 34 All information subject to change without notice. DDC-SVC-MAN-0041 Copyright © 2009 DETROIT DIESEL CORPORATION