PERIODICAL CHANGE OF THE SAFETY-RELATED COMPONENTS 4.6.1.4 BOOM HYDRAULIC SYSTEM 1 5 1 2 5 6 4 RKA02400 184 No. Components related to safety that periodically need changing Q.ty Change i nterval 1 Hydraulic pipe (iron pipe - extension boom iron pipe) 2 2 2 Every 2 y ever occu 1 2 1 ears or 1000 hours, which- rs first 2 Hydraulic pipe (iron pipe - extension cylinder) 3 Hydraulic pipe (iron pipe - equipment carrier iron pipe) 4 Hydraulic pipe (iron pipe - equipment carrier cylinder) 5 Hydraulic pipe (iron pipe - auxiliary system iron pipe) 6 Hydraulic pipe (pipe - optional equipment)