CLAAS ARGO K50, K60, K70 — SECTION 3 TECHNICAL DATA

TECHNICAL DATA 3.5 K50 K60 K70 Hydraulics Pump type Load sensing Load sensing Load sensing Primarysystemmax.pressure bar 250 250 250 Primarysystemmaxflow (Up to Machines S/No.51200471) (FromMachines S/No.51200472) l/min l/min 122 @2300 rpm 122 @2200 rpm 122 @2300 rpm 122 @2200 rpm 122 @2300 rpm 122 @2200 rpm Primarysystem(load sensing) bar 14 14 14 Primarysystem(standby) bar 20 20 20 Secondarysystemmax.pressure bar 160 160 160 Secondarysystemmaxflow l/min 50 50 50 No.ofaux.services option 2 front,1 rear 2 front,1 rear 2 front,1 rear Electrics Batterycapacity Amp/hr 128 128 128 Alternatoroutput Amp 65 65 65 Capacities Hydraulic system litre 128 128 128 Hydraulic tank litre 67 67 67 Fueltank litre 200 200 200 Engine oil litre 9 9 9 Engine coolant litre 31 31 31 Transmission litre 16 16 16 Transmissiontransferbox litre 0.4 0.4 0.4 Axle -front litre 9.5 9.5 9.5 Axle -rear litre 10 10 10 Axle -finaldrive (each) litre 0.8 0.8 0.8 Screenwash litre 6.5 6.5 6.5