Komatsu — CLEAN INSIDE OF COOLING SYSTEM

. MAINTENANCE SERVICE PROCEDURE MAINTENANCE SERVICE PROCEDURE remove. 4 - 21 2. Turn main radiator cap (4) an d sub radiator cap (5) slowly, and 3. Prepare a container to catch t he coolant, pull out hose (6) of the main radiator at the bottom front right of the machine, then n the water. open drain valve (7) and drai The sub radiator is at the bot tom front left of the machine. Pull out drain hose (8) in the sam and drain the water. e way, then open drain valve (9) 4. Open the drain valve (11) in t he water pump piping on the right side of the engine, and drain the coolant. 5. After draining the antifreeze solution, close drain valve (7), (9) and (11), then fill with clean w ater.

After the radiator is filled with water, start and run the eng ine at low idling speed. After the water temperature rises abo for about 10 minutes. ve 90°C (194°F), run the engine valve (7), (9) and (11), and drain 6. Stop the engine, open drain the water. 7. After draining the water, clea n the cooling system with cleaning agent. For the cleaning method, se e the instructions for the cleaning agent. (11). or, then open each valve (3). or replacing the corrosion resistor, CORROSION RESISTOR 8. Close drain valve (7), (9) and 9. Replace the corrosion resist For details of the procedure f see "REPLACE MAIN 10. CARTRIDGE AND SUB CARTRIDGE (PAGE 4-68)". Add coolant mixed with anti water filler.

Decide the proportions of anti CORROSION RESISTOR freeze until it overflows from the freeze and water according to the table for the mixing rate of w ater and antifreeze. 11. To bleed the air from the coo ling system, run the engine at low idle for 5 minutes, and for a further 5 minutes at high idle. adiator cap off.) (When doing this, leave the r