Mack Trucks — 5-113.bk

Expansion Plug Replacement Valve Inspection [213 FP] 1. Inspect the valves for cracks, pits and other conditions that may cause improper operation. The cylinder head has three expansion plugs of different sizes. 2. Inspect the stem ends of the valves for nicks and burrs that may damage the seals at assembly. 29 mm (1-9/64 or 1.142 inch) 40 mm (1-37/64 or 1.575 inch) 3. Measure the valve seat angle. 50 mm (1-31/32 or 1.968 inch) 4. Measure valve stem length and diameter. All are installed using the following procedure: 5. Discard and replace damaged or worn valves. 1. Clean the plug bore thoroughly. 2. Apply Loctite ® 277 sealer, or equivalent, to the expansion plug and plug bore. 3.

Using a socket, extension and a hammer, press the expansion plug into the plug bore. 4. Repeat steps 1–3 for each new plug. The plug should be installed flush to 0.508 mm (0.020 inch) below the surface. 265 Figure 265 — Expansion Plug Installation Page 171 REPAIR INSTRUCTIONS, PART 1 1. Socket and Extension 2. Hammer