25 Figure 25 — Unit Injector — Injection and Pressure Drop Phases Injection phase (C): The injection phase begins when the fuel valve closes. The camshaft lobe and rocker arm continue to press down on the pump plunger and injection occurs as the path through the fuel valve closes. The injection phase continues as long as the fuel valve is closed. The dimension by which the injector nozzle extends from the head is critical. This means that machining the head in any way that changes this nozzle extension is not permitted. Pressure drop phase (D): The injection phase ends when the fuel valve opens and pressure in the unit injector drops below the nozzle opening pressure.
The fuel flows through the open fuel valve, through the unit injector holes and out through the fuel gallery. Note that the fuel valve position (closed or open) determines when the injection phase begins and ends. The time during which the fuel valve is closed determines the amount of fuel injected at each pump stroke. 26 Unit injectors are categorized and coded with regard to tolerances. Whenever a unit injector is replaced, the replacement injector MUST be programmed for the cylinder in which it is installed. This is done by programming EECU parameters using the VCADS pro or the Premium Tech Tool (PTT) to set Injector Trim parameters with the trim codes marked on the injectors.
Figure 26 — Injector Coding Page 32 DESCRIPTION AND OPERATION 1. Pump Plunger 2. Fuel Gallery 3. Injector Nozzle 1. Serial No. 2. Unit Calibration No.