Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — REMOVAL AND INSTALLATION OF POWER TRAIN AND LUBRICATING OIL PUMP ASSEMBLY

SEN00951-00 50 Disassembly and assembly Removal and installation of power train and lubricating oil pump assembly 1 5. Lift off power train and lubricating oil pump assembly (4). [*1] 4 Power train and lubricating oil pump assembly: 15 kg Removal k Disconnect the cable from the negative (–) terminal of the battery. 1. Remove the floor frame assembly. For details, see "Removal and installation of floor frame assembly." 2. Remove the undercover. 3. Disconnect tube (1) under the power train and lubricating oil pump assembly. Installation q Carry out installation in the reverse order to removal. [*1] 3 Mounting bolt: 98 – 123 Nm {10 – 12.5 kgm} 4. Disconnect tubes (2) and (3).

q Refilling with oil Add oil through the oil filler to the specified level. Run the engine to circulate the oil through the system. Then, check the oil level again. 6 D65EX, PX, WX-15E0