Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — HSS PUMP

10 Structure, function and maintenance standard SEN00285-01 3. Variable throttle valve (1) Operation in direction for maximum pump delivery q The opening area of part (A) increases and the oil flowing from the large diameter end of servo piston (1) through port (c) to port (b) is not lim- ited and the moving speed of servo piston (1) is heightened. q Pump discharge pressure (PP) enters the vari- able throttle valve through port (a). q If the pressure becomes higher than the force of spring (3) because of the difference in sec- tional area of spool (4) in chamber (e), spool (4) moves to the right.

1) When main pump pressure (PP) is high (2) Operation in the direction for smaller pump discharge amount q The hydraulic oil flows from port (b) through port (c) to the large diameter side of servo pis- ton (1). q If spool (4) moves to the right, the opening area between ports (c) and (b) is reduced by the notch at part (A). Accordingly, less oil flows from the large diameter end of servo piston (1) and the moving speed of servo piston (1) is lowered. q Spool (4) operates according to main pump pressure (PP) as explained in the above sec- tion.

2) When main pump pressure (PP) is low q Even if main pump pressure (PP) enters cham- ber (e) through port (a), spool (4) pushes spring (3) less strongly and moves to the right for shorter distance. D65EX, PX, WX-15E0 27